Industry diesel generator set
VOLVO Line 250-800KVA
Renowned globally for their engineering excellence, Volvo diesel offer outstanding reliability and fuel efficiency, ensuring optimal performance in even the most demanding environments. Volvo focus on quality, safety and environmental protection, so Volvo engine features low emission, low fuel consumption and low power derating at high altitude.
Yorking Volvo Series diesel generator sets range from 250kVA to 800kVA. Engineered to excel under extreme conditions, Volvo generators are ideal for applications in sectors such as mining and high altitude. Their strong adaptability to harsh environment ensures consistent power delivery, making them a trusted choice for critical operations.
Model | Prime | Standby | Engine | Alternator | Dimension(LxWxH)(MM) | |||||
kVA | kW | kVA | kW | Model | Governor | Stamford | Leroy Somer | Silent type | ||
Three phase | ||||||||||
YDV275E3/S3 | 250 | 200 | 275 | 220 | TAD841GE | CR | S4L1D-E | TAL A46 D | 3650*1300*2000 | |
YDV330E3/S3 | 300 | 240 | 330 | 264 | TAD842GE | CR | S4L1S-D | TAL A46 F | 3880*1460*2150 | |
YDV358E3/S3 | 325 | 260 | 358 | 286 | TAD843GE | CR | UCI274J | TAL A46 G | 3880*1460*2150 | |
YDV345E3/S3 | 314 | 251 | 345 | 276 | TAD1341GE-B | CR | S4L1D-E | TAL A46 G | 4160*1600*2220 | |
YDV385E3/S3 | 350 | 280 | 385 | 308 | TAD1342GE-B | CR | S4L1D-E | TAL A46 H | 4160*1600*2220 | |
YDV415E3/S3 | 378 | 302 | 415 | 332 | TAD1343GE-B | CR | S4L1D-F | TAL A473 A | 4160*1600*2220 | |
YDV450E3/S3 | 409 | 327 | 450 | 360 | TAD1344GE-B | CR | S4L1D-F | TAL A473A | 4230*1600*2220 | |
YDV495E3/S3 | 450 | 360 | 495 | 396 | TAD1345GE-B | CR | S4L1D-G | TAL A473 B | 4230*1600*2220 | |
YDV505E3/S3 | 460 | 368 | 506 | 405 | TAD1640GE-B | CR | S5L1D-C | TAL A473 C | 4690*1680*2280 | |
YDV550E3/S3 | 500 | 400 | 550 | 440 | TAD1641GE-B | CR | S5L1D-C | TAL A473 E | 4690*1680*2280 | |
YDV650E3/S3 | 594 | 475 | 653 | 523 | TAD1642GE-B | CR | S5L1D-E | TAL A473 E | 4690*1680*2280 | |
YDV715E3/S3 | 650 | 520 | 715 | 572 | TWD1644GE | CR | S5L1D-F | TAL A473 F | 5080*1780*2530 | |
YDV770E3/S3 | 700 | 560 | 770 | 616 | TWD1645GE | CR | S5L1D-G | TAL A49 B | 5080*1780*2530 |
Model | Prime | Standby | Engine | Alternator | Dimension(LxWxH)(MM) | |||||
kVA | kW | kVA | kW | Model | Governor | Stamford | Leroy Somer | Silent type | ||
Three phase | ||||||||||
YDV275E3/S3 | 250 | 200 | 275 | 220 | TAD841GE | CR | UCI274J | TAL A46 E | 3650*1300*2000 | |
YDV330E3/S3 | 300 | 240 | 330 | 264 | TAD842GE | CR | UCI274J | TAL A46 G | 3880*1460*2150 | |
YDV344E3/S3 | 313 | 250 | 344 | 275 | TAD843GE | CR | UCI274J | TAL A46 G | 3880*1460*2150 | |
YDV364E3/S3 | 331 | 265 | 364 | 292 | TAD1341GE-B | CR | S4L1S-D | TAL A46 H | 4160*1600*2220 | |
YDV440E3/S3 | 400 | 320 | 440 | 352 | TAD1342GE-B | CR | S4L1S-F | TAL A473 A | 4160*1600*2220 | |
YDV450E3/S3 | 410 | 328 | 451 | 361 | TAD1343GE-B | CR | S4L1S-F | TAL A473 A | 4160*1600*2220 | |
YDV500E3/S3 | 456 | 365 | 502 | 402 | TAD1344GE-B | CR | S4L1S-F | TAL A473 B | 4230*1600*2220 | |
YDV500E3/S3 | 456 | 365 | 502 | 402 | TAD1345GE-B | CR | S4L1S-F | TAL A473 B | 4230*1600*2220 | |
YDV550E3/S3 | 500 | 400 | 550 | 440 | TAD1640GE-B | CR | S4L1S-F | TAL A473 C | 4690*1680*2280 | |
YDV625E3/S3 | 569 | 455 | 626 | 501 | TAD1641GE-B | CR | S5L1S-D | TAL A473 E | 4690*1680*2280 | |
YDV690E3/S3 | 625 | 500 | 688 | 550 | TAD1642GE-B | CR | S5L1S-D | TAL A473 F | 4690*1680*2280 | |
YDV750E3/S3 | 683 | 546 | 751 | 601 | TWD1644GE | CR | S5L1S-F | TAL A49 B | 5080*1780*2530 | |
YDV800E3/S3 | 728 | 582 | 800 | 640 | TWD1645GE | CR | S5L1S-F | TAL A49 B | 5080*1780*2530 |